We Provide the Range of Expectations

Pencil Foot Control Universal Shaft 1.6 & 2.4mm

 1

Applications

Instruction for Use

Download

Available Options

ThumbnailSKUArticle NumberConnectorPencil TypesTotal Length
317A4MM International Bowa, ICC Erbe Vio, Eschmann, ConmedSTANDARD3M
317D4MM International Bowa, ICC Erbe Vio, Eschmann, ConmedSTANDARD5M
NS317A4MM International Bowa, ICC Erbe Vio, Eschmann, ConmedNONSTICK3M
NS317D4MM International Bowa, ICC Erbe Vio, Eschmann, ConmedNONSTICK5M
347A8MM, Erbe T-Series Valleylab, Erbe InternationalSTANDARD3M
347D8MM, Erbe T-Series Valleylab, Erbe InternationalSTANDARD5M
NS347A8MM, Erbe T-Series Valleylab, Erbe InternationalNONSTICK3M
NS347D8MM, Erbe T-Series Valleylab, Erbe InternationalNONSTICK5M
318A5MM, Erbe ACC Series Standard ICC Series Vio, Karl StorzSTANDARD3M
318D5MM, Erbe ACC Series Standard ICC Series Vio, Karl StorzSTANDARD5M
NS318A5MM, Erbe ACC Series Standard ICC Series Vio, Karl StorzNONSTICK3M
NS318D5MM, Erbe ACC Series Standard ICC Series Vio, Karl StorzNONSTICK5M
354AMartin, Erbe, T-Series, Integra Berchtold, AesculapSTANDARD3M
354DMartin, Erbe, T-Series, Integra Berchtold, AesculapSTANDARD5M
NS354AMartin, Erbe, T-Series, Integra Berchtold, AesculapNONSTICK3M
NS354DMartin, Erbe, T-Series, Integra Berchtold, AesculapNONSTICK5M

Additional information

Regulatory Compliance

MDD 93/42/EEC (Class Is / IIb), MDR 2017/745 (Transiting)

Manufacturing Unit

Fully Compliant under ISO 13485:2016 QMS

Product Classification

Class IIb as per Annex VIII, Chapter III Rule 9
Non-measuring, Transient use, Surgically invasive, Active Medical Device

Biocompatibility

Tested and compliant with ISO 10993 series standards

Primary Material

Validated Medical Grade Polymers

Secondary Material

Medical Grade AISI 210/220 Stainless Steel

Surface Finish

Polished passivated, corrosion resistance

Safety Compliance

REACH and RoHS compliant

Manufacturing Environment

Assembled and packed in controlled environment

Reprocessing Status

Yes, it is Reusable Product. See IFU for reprocessing info

Reprocessing Method

Validated Steam Autoclave (121°C – 135°C, 3–5 min Holding Time)

Chemical Disinfection

CE-Certified validated agent suitable for Electrosurgical Instruments

EMDN Code

L180601

Packaging Unit

Individually packed (1 piece per unit) / 20 units per box

Minimum Order Quantity

20 Pieces / 01 Box

Manufacturer

Electro Range MFG Co. – ERMC®

x

Contact With Us!

250 Meter Daska Road Ghuinke Sialkot 51310 Pakistan
Call us: +92 321 610 0080
24/7 Customer Support